Unit 1: Cell Counting - Practice Quiz

BTY114 — Cell Biology Laboratory 60 Questions
0 Correct 0 Wrong 60 Left
0/60

1 What is the main purpose of a Neubauer chamber?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. To separate living cells
B. To sterilize the cell sample
C. To measure cell concentration
D. To measure solution pH

2 What type of instrument is a Neubauer chamber?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. A culture flask
B. A staining bottle
C. A filtration unit
D. A counting slide

3 What is the usual depth of the counting chamber under the coverslip?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. mm
B. mm
C. mm
D. mm

4 Which instrument is used to observe cells in a Neubauer chamber?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. A spectrophotometer
B. A compound microscope
C. A pH meter
D. A centrifuge

5 Why is a coverslip placed on a Neubauer chamber?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. To create a known chamber depth
B. To increase the sample temperature
C. To change the cell color
D. To remove the liquid sample

6 What should be done before loading a yeast or bacterial suspension into the chamber?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. Freeze the suspension completely
B. Dry the suspension on glass
C. Mix the suspension gently
D. Boil the suspension briefly

7 What is the purpose of diluting a dense cell suspension?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. To remove the chamber markings
B. To increase the chamber depth
C. To make cells easier to count
D. To make cells grow faster

8 If a sample is diluted tenfold, what is its dilution factor?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. 100
B. 10
C. 0.1
D. 1

9 Which unit is commonly used to report yeast or bacterial concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. Cells per mL
B. Cells per hour
C. Cells per kg
D. Cells per meter

10 Why are several squares counted in a Neubauer chamber?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. To increase the sample volume
B. To obtain a more reliable average
C. To change the dilution factor
D. To remove all cell clumps

11 What should be done if the chamber contains too many cells to distinguish individually?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. Dilute the sample further
B. Increase the coverslip thickness
C. Use a larger pipette tip
D. Remove the grid markings

12 What should be done if very few cells are present in the counted squares?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. Count more squares
B. Discard the microscope
C. Remove the coverslip
D. Increase the chamber depth

13 What is the usual rule for cells touching the boundary lines?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. Count every boundary cell
B. Ignore all boundary cells
C. Count only bottom boundary cells
D. Count two selected boundaries

14 What is the approximate volume above a mm² square with a chamber depth of mm?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. mm³
B. mm³
C. mm³
D. mm³

15 What is the main reason for avoiding air bubbles when loading the chamber?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. They remove the grid pattern
B. They increase cell concentration
C. They interfere with accurate counting
D. They sterilize the suspension

16 What does the average cell count represent?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. The largest count in one square
B. The mean count per selected square
C. The total chamber depth
D. The smallest count in one square

17 If 40 cells are counted in 4 equal squares, what is the average count per square?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. 10 cells
B. 40 cells
C. 4 cells
D. 160 cells

18 If the average count is 20 cells and the dilution factor is 5, which value increases the estimated original concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. The coverslip color
B. The microscope brand
C. The grid line thickness
D. The dilution factor

19 Which cells should generally be counted as separate cells?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. Only cells outside the grid
B. Only cells hidden by bubbles
C. Only cells below the chamber
D. Clearly separated cells

20 What should be recorded during a Neubauer chamber count?

Counting of yeast /bacterial cells using a Neubauer chamber Easy
A. Only the microscope color
B. Only the sample container size
C. Counts from each selected square
D. Only the room temperature

21 A yeast suspension is diluted 1:10. The average count is 85 cells in each of five central Neubauer squares. Each square has a volume of . What is the cell concentration in the original suspension?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A.
B.
C.
D.

22 A bacterial sample is diluted 1:100, and 120 cells are counted in a Neubauer square measuring with a chamber depth of . What is the concentration in the original sample?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A.
B.
C.
D.

23 A student counts 48, 52, 50, and 54 yeast cells in four equivalent Neubauer squares. The sample was diluted 1:20, and each square has a volume of . What is the original concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A.
B.
C.
D.

24 A yeast suspension gives an average of 64 cells per central square after a 1:5 dilution. If each counted square represents , how many cells are present in of the original suspension?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. cells
B. cells
C. cells
D. cells

25 A student counts 75 cells in a square but forgets to apply a 1:4 dilution factor. The square volume is . What value will the student report, and what is the correct original concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. reported; correct
B. reported; correct
C. reported; correct
D. reported; correct

26 In a bacterial count, the following numbers are obtained from five squares: 31, 29, 30, 48, and 32. Which procedure is most appropriate before calculating the final concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. Repeat the count because one value is inconsistent
B. Use all five counts without checking variation
C. Use only the two lowest counts for calculation
D. Discard the highest count and average the rest

27 A diluted yeast sample has an average count of 40 cells per square. The square volume is , and the dilution factor is 25. What dilution would produce approximately 100 cells per square under the same conditions?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. A 1:10 dilution
B. A 1:50 dilution
C. A 1:25 dilution
D. A 1:5 dilution

28 A cell lies exactly on the boundary between two Neubauer squares. Which counting rule reduces the risk of counting the same cell twice?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. Count cells touching the bottom and right boundaries
B. Count every boundary cell in both adjacent squares
C. Count cells touching the top and right boundaries
D. Count cells touching the top and left boundaries

29 A yeast suspension is mixed with methylene blue. Among 200 total cells counted, 150 are unstained and 50 are blue. What are the viability and percentage of dead cells?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. 80% viable and 20% dead
B. 75% viable and 25% dead
C. 25% viable and 75% dead
D. 50% viable and 50% dead

30 A student loads a Neubauer chamber without allowing the suspension to enter by capillary action. The cells are concentrated near the loading point. What is the most likely effect on the result?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. The chamber volume becomes larger than calibrated
B. The count may be biased because distribution is uneven
C. The dilution factor automatically becomes doubled
D. The count is reliably representative of the sample

31 A bacterial sample is diluted by mixing of culture with of diluent. What is the dilution factor of the resulting sample?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. 2
B. 5
C. 20
D. 10

32 A student counts 90 cells in five central squares. Each square has a volume of . If the sample was diluted 1:10, what is the correct formula for the original concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A.
B.
C.
D.

33 A yeast sample has an original concentration of . What dilution is needed to obtain approximately 80 cells in a square of volume ?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. 1:50 dilution
B. 1:25 dilution
C. 1:10 dilution
D. 1:5 dilution

34 A student obtains 62, 64, 61, and 63 cells in four squares. Which reported average is most appropriate?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. 63.5 cells per square
B. 62.5 cells per square
C. 64 cells per square
D. 61 cells per square

35 A bacterial suspension is too concentrated, and the cells overlap in the Neubauer chamber. What is the best corrective action?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. Increase the chamber depth manually
B. Dilute the suspension and reload it
C. Add stain until the cells separate
D. Count only the visible outer cells

36 A yeast suspension contains clumps, and each clump is counted as one unit. How will this usually affect the calculated cell concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. It will not affect the concentration under any condition
B. It will usually underestimate the number of individual cells
C. It will change only the chamber depth measurement
D. It will usually overestimate the number of individual cells

37 A student counts 56 cells in a square of volume after a 1:20 dilution. The sample was prepared by mixing of culture with of stain. What is the concentration in the original culture before staining?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A.
B.
C.
D.

38 A yeast count is performed in a chamber with a depth of . If the counting area is , what volume is represented by that area?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A.
B.
C.
D.

39 Two counts from the same bacterial sample are and . What is the mean concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A.
B.
C.
D.

40 A student counts 25 bacteria in a square represented by after a 1:100 dilution. The sample is then diluted an additional tenfold before a second count. Approximately how many bacteria should be expected in the same square during the second count?

Counting of yeast /bacterial cells using a Neubauer chamber Medium
A. 2.5 bacteria
B. 25 bacteria
C. 0.25 bacteria
D. 250 bacteria

41 A yeast suspension is diluted 1:20 before loading. The four corner squares contain 82, 76, 79, and 83 cells. Assuming each corner square has a volume of , what is the original concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.

42 Using the standard boundary convention for a Neubauer chamber, which cells should be included when counting a square?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. Cells touching all four boundaries
B. Cells touching the top and left boundaries
C. Cells touching the bottom and left boundaries
D. Cells touching the top and right boundaries

43 A bacterial suspension diluted 1:100 gives a total of 125 bacteria in five central groups. Each group has an area of , and the chamber depth is . What was the concentration in the original suspension?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.

44 A sample is prepared by mixing of culture with of sterile diluent, followed by mixing of that suspension with of diluent. What is the final dilution relative to the original culture?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. 1:20
B. 1:100
C. 1:200
D. 1:50

45 A yeast suspension is expected to contain approximately . If the desired mean count is about 50 cells in one large square of volume , which dilution should be prepared?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. 1:25
B. 1:5
C. 1:10
D. 1:50

46 Four equivalent squares yield counts of 49, 51, 100, and 50 yeast cells. Which interpretation is most appropriate before calculating concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. Reload after remixing the suspension
B. Multiply the highest count by four
C. Average all four counts directly
D. Discard the two lowest counts

47 If 400 bacterial cells are counted in a chamber volume and counting follows Poisson statistics, what is the approximate relative counting uncertainty caused by random sampling alone?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. 20.0%
B. 10.0%
C. 2.5%
D. 5.0%

48 A chamber has a calibrated depth of , but it is accidentally loaded to a depth of . If the analyst still uses the nominal depth in the calculation, how is the concentration affected?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. It is overestimated by 20%
B. It is underestimated by 20%
C. It is unaffected by the depth error
D. It is underestimated by 16.7%

49 A bacterial count is made in five central groups, each measuring , with a chamber depth of . Which volume should be used for the five groups together?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.

50 A 1:1 mixture of yeast culture and viability stain produces a mean count of 72 viable cells per large square. The large-square volume is . What is the viable concentration in the original culture?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.

51 A yeast sample is diluted 1:25 and counted in four large squares. The counts are 62, 58, 61, and 59. Each square represents . What is the best estimate of the original concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.

52 In the calculation described in the previous measurement, which value is the correct original concentration when the mean count is 60 cells, the square volume is , and the dilution is 1:25?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.

53 Two chambers are loaded from the same bacterial dilution. Chamber A gives 118 cells in five central groups, whereas chamber B gives 163 cells. Which conclusion is most defensible?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. Average them without qualification
B. Use the higher count only
C. Use the lower count only
D. Investigate loading or sample nonuniformity

54 A researcher counts 24 bacteria in a five-group area and obtains a calculated concentration of . Which change would most improve precision without changing the sample concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. Increase the microscope magnification only
B. Count fewer groups
C. Count a larger total volume
D. Use a greater dilution

55 A yeast suspension contains many clumps, and each clump is recorded as one object. Compared with a properly dispersed suspension, what is the most likely result?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. Cell concentration is underestimated
B. Dilution factor is increased
C. Cell concentration is overestimated
D. Chamber volume is decreased

56 A bacterial dilution is prepared by adding of culture to of diluent. The diluted sample produces 90 bacteria in five central groups. What is the original concentration?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.

57 When counting bacteria in a central grid, an analyst counts the same boundary bacterium in two adjacent squares. What type of error has been introduced?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. A systematic double-counting error
B. A chamber-depth calibration error
C. A microscope-resolution error
D. A random dilution error

58 A student obtains 420, 18, and 2 cells in three serially diluted preparations. Which preparation is generally most suitable for a reliable Neubauer count, assuming the same counted volume?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. The preparation containing 420 cells
B. All preparations are equally suitable
C. The preparation containing 18 cells
D. The preparation containing 2 cells

59 A chamber is loaded with a bacterial suspension containing air bubbles. Counts from different regions vary from 35 to 110 cells. What is the best immediate response?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A. Count only the clearest region
B. Average all regions
C. Remove and reload the chamber
D. Multiply the lowest count by three

60 A yeast culture is counted after a 1:4 dilution. The mean count is 45 cells in a large square of volume . If the culture is intended to be seeded at , what volume of the original culture is required to prepare of inoculum?

Counting of yeast /bacterial cells using a Neubauer chamber Hard
A.
B.
C.
D.