Notice: Due to an ongoing migration of our storage and publishing system, material requested since last month will not be uploaded for the time being, and new requests are paused. All existing notes remain available.

Unit 3 MCQs Antigen - antibody interactions

BTS511 — Immunology 60 questions. Pick an option to check it.

Read the notes Subjective questions

0 of 60 answered 0 right 0 wrong , 60 left

  1. Question 1 of 60 strength of antigen antibody interaction Easy

    The affinity of an antibody refers to which of the following?

  2. Question 2 of 60 strength of antigen antibody interaction Easy

    The term avidity best describes which concept?

  3. Question 3 of 60 strength of antigen antibody interaction Easy

    Which antibody class generally has the highest avidity due to its multiple binding sites?

  4. Question 4 of 60 cross reactivity Easy

    Cross-reactivity occurs when an antibody binds to which of the following?

  5. Question 5 of 60 cross reactivity Easy

    Which classic example demonstrates cross-reactivity in blood group serology?

  6. Question 6 of 60 precipitation Easy

    A precipitation reaction typically involves an antibody reacting with which type of antigen?

  7. Question 7 of 60 precipitation Easy

    In a precipitation curve, maximum precipitate forms in which zone?

  8. Question 8 of 60 precipitation Easy

    Which technique uses precipitation in a gel where both antigen and antibody diffuse toward each other?

  9. Question 9 of 60 agglutination Easy

    Agglutination reactions involve antibodies reacting with which type of antigen?

  10. Question 10 of 60 agglutination Easy

    The clumping of red blood cells by antibodies is specifically called what?

  11. Question 11 of 60 agglutination Easy

    The prozone phenomenon in agglutination is caused by which condition?

  12. Question 12 of 60 radioimmunoassay Easy

    In a radioimmunoassay (RIA), what is used as the label to detect antigen-antibody binding?

  13. Question 13 of 60 radioimmunoassay Easy

    Radioimmunoassay is particularly valued for which of the following characteristics?

  14. Question 14 of 60 enzyme linked immunosorbent assay Easy

    In an ELISA, the label attached to the antibody is typically which of the following?

  15. Question 15 of 60 enzyme linked immunosorbent assay Easy

    In a sandwich ELISA, the antigen is captured between which two components?

  16. Question 16 of 60 enzyme linked immunosorbent assay Easy

    A positive ELISA result is most commonly detected as which observable change?

  17. Question 17 of 60 immunofluorescence Easy

    Immunofluorescence uses antibodies labeled with what type of molecule?

  18. Question 18 of 60 immunofluorescence Easy

    Which fluorescent dye is commonly used to label antibodies and emits green light?

  19. Question 19 of 60 immunofluorescence Easy

    In direct immunofluorescence, the fluorochrome is attached to which antibody?

  20. Question 20 of 60 immunoblot Easy

    The Western blot (immunoblot) technique is used to detect which type of molecule?

  21. Question 21 of 60 strength of antigen antibody interaction Medium

    Antibody A binds an epitope with an affinity constant , while Antibody B binds the same epitope with . What can be concluded?

  22. Question 22 of 60 strength of antigen antibody interaction Medium

    Why does IgM often show high avidity despite its individual binding sites having relatively low affinity?

  23. Question 23 of 60 cross reactivity Medium

    A patient recovering from a streptococcal infection develops antibodies that also react with heart tissue. This phenomenon is best explained by:

  24. Question 24 of 60 cross reactivity Medium

    In an ELISA, an antiserum raised against Antigen X also gives a positive signal with Antigen Y. Which is the most likely explanation?

  25. Question 25 of 60 precipitation Medium

    In a precipitation reaction, maximum precipitate forms at the zone of equivalence. What happens in the zone of antibody excess?

  26. Question 26 of 60 precipitation Medium

    In radial immunodiffusion, the diameter of the precipitin ring is related to antigen concentration in what way?

  27. Question 27 of 60 precipitation Medium

    In the Ouchterlony double diffusion test, two adjacent antigens form precipitin lines that fuse smoothly into a continuous arc. This indicates the antigens are:

  28. Question 28 of 60 agglutination Medium

    The prozone phenomenon in an agglutination test results in a false-negative result because:

  29. Question 29 of 60 agglutination Medium

    Why is the Coombs (antiglobulin) test needed to detect certain anti-Rh antibodies on red blood cells?

  30. Question 30 of 60 agglutination Medium

    In passive (indirect) hemagglutination, soluble antigen is first adsorbed onto red blood cells. What is the purpose of this step?

  31. Question 31 of 60 radioimmunoassay Medium

    In a competitive radioimmunoassay (RIA), how does the measured radioactive signal relate to the amount of unlabeled antigen in the sample?

  32. Question 32 of 60 radioimmunoassay Medium

    Which property makes RIA particularly useful for measuring hormones present at very low concentrations?

  33. Question 33 of 60 enzyme linked immunosorbent assay Medium

    In a sandwich ELISA, the antigen is captured between two antibodies. What is a key requirement of the antigen for this format to work?

  34. Question 34 of 60 enzyme linked immunosorbent assay Medium

    In an indirect ELISA measuring antibody in a patient's serum, what does the enzyme-conjugated secondary antibody bind to?

  35. Question 35 of 60 enzyme linked immunosorbent assay Medium

    If the substrate is added to an ELISA well but no color develops in a sample expected to be positive, which is the most likely technical cause?

  36. Question 36 of 60 immunofluorescence Medium

    In indirect immunofluorescence, why can a single fluorochrome-labeled secondary antibody be used with many different primary antibodies?

  37. Question 37 of 60 immunofluorescence Medium

    A researcher wants to simultaneously visualize two different proteins in the same cell using immunofluorescence. What is the essential requirement?

  38. Question 38 of 60 immunoblot Medium

    In a Western blot, proteins are separated by SDS-PAGE before transfer to a membrane. What property primarily determines this separation?

  39. Question 39 of 60 immunoblot Medium

    During a Western blot, why is the membrane incubated with a blocking agent such as non-fat milk before adding the primary antibody?

  40. Question 40 of 60 immunohistochemistry Medium

    In immunohistochemistry (IHC), what is the main advantage compared to immunofluorescence for routine diagnostic tissue examination?

  41. Question 41 of 60 strength of antigen antibody interaction Hard

    The intrinsic affinity of an antibody for a monovalent hapten is described by the association constant . If at equilibrium the concentration of free hapten equals the reciprocal of , what fraction of antibody binding sites are occupied?

  42. Question 42 of 60 strength of antigen antibody interaction Hard

    Two antibodies, X and Y, bind the same multivalent antigen. Antibody X has higher intrinsic affinity per site, but antibody Y shows higher functional avidity in cell-binding assays. Which explanation is most consistent with these observations?

  43. Question 43 of 60 cross reactivity Hard

    An antiserum raised against antigen A reacts with antigen B at 20% of its titer against A. Scatchard-type analysis shows the anti-A antibodies bind B with a that is 5-fold lower than for A. Which interpretation is most accurate?

  44. Question 44 of 60 cross reactivity Hard

    In the ABO blood group system, anti-A and anti-B isohemagglutinins arise without prior transfusion. What best explains their origin through cross-reactivity?

  45. Question 45 of 60 precipitation Hard

    In a quantitative precipitin curve, increasing antigen beyond the equivalence zone causes the amount of precipitate to decrease. What is the mechanistic reason for this prozone-analogous 'postzone' behavior?

  46. Question 46 of 60 precipitation Hard

    In double immunodiffusion (Ouchterlony), two adjacent antigen wells are tested against a central antiserum. The precipitin lines cross each other forming an X. What does this pattern indicate?

  47. Question 47 of 60 precipitation Hard

    In radial immunodiffusion (Mancini method) at endpoint, the relationship between the diameter of the precipitin ring and antigen concentration is best described as:

  48. Question 48 of 60 agglutination Hard

    A serum with a very high antibody titer gives a negative agglutination result at low dilution but strong agglutination at higher dilutions. What phenomenon explains the false negative at low dilution?

  49. Question 49 of 60 agglutination Hard

    The antiglobulin (Coombs) test is required to detect certain anti-Rh antibodies in hemagglutination assays. Why do these antibodies fail to directly agglutinate red cells?

  50. Question 50 of 60 radioimmunoassay Hard

    In a competitive RIA, patient sample analyte competes with a fixed amount of radiolabeled analyte for limited antibody. As the concentration of unlabeled analyte in the sample increases, the bound radioactivity signal:

  51. Question 51 of 60 radioimmunoassay Hard

    A researcher wishes to improve the lower limit of detection of a competitive RIA. Which change would most effectively lower the detection limit?

  52. Question 52 of 60 enzyme linked immunosorbent assay Hard

    In a sandwich ELISA at very high analyte concentrations the measured signal paradoxically falls, giving a hook effect. What is the underlying cause?

  53. Question 53 of 60 enzyme linked immunosorbent assay Hard

    A competitive ELISA and a sandwich ELISA are compared for measuring a small hapten (~400 Da). Which format is appropriate and why?

  54. Question 54 of 60 enzyme linked immunosorbent assay Hard

    In an indirect ELISA measuring anti-viral IgG, background signal is unacceptably high in negative controls. Which single change most specifically reduces nonspecific binding without affecting true signal?

  55. Question 55 of 60 immunofluorescence Hard

    In indirect immunofluorescence, a primary rabbit antibody is detected with a fluorophore-labeled anti-rabbit secondary. Compared with direct immunofluorescence, the indirect method gives stronger signal primarily because:

  56. Question 56 of 60 immunofluorescence Hard

    When performing dual-color immunofluorescence with FITC (green) and a red fluorophore, bleed-through causes the FITC channel to show false red-region signal. Which correction is most appropriate?

  57. Question 57 of 60 immunoblot Hard

    In a Western blot, a protein known to be 50 kDa migrates as a band at ~100 kDa under non-reducing conditions but at 50 kDa with reducing SDS-PAGE. The most likely explanation is:

  58. Question 58 of 60 immunoblot Hard

    A Western blot shows the target band plus several unexpected higher- and lower-molecular-weight bands. Which action best distinguishes genuine cross-reactivity of the antibody from proteolytic degradation of the target?

  59. Question 59 of 60 immunohistochemistry Hard

    In formalin-fixed paraffin-embedded tissue, an antibody that works on frozen sections gives no staining. Which pretreatment most directly addresses the likely cause?

  60. Question 60 of 60 immunohistochemistry Hard

    In an IHC assay of a tissue rich in endogenous peroxidase using an HRP-based detection system, strong staining appears even in the no-primary-antibody control. The most appropriate corrective step is:

That's unit 3

Answer a few questions and your score shows up here.