1Which method is commonly used to determine total nitrogen in organic manures?
Determination of total nitrogen in organic manures
Easy
A.Turbidimetric method
B.Flame photometric method
C.Kjeldahl method
D.EDTA titration method
Correct Answer: Kjeldahl method
Explanation:
The Kjeldahl method is commonly used to determine total nitrogen in organic manure samples.
Incorrect! Try again.
2Which acid is commonly used to digest an organic manure sample in the Kjeldahl method?
Determination of total nitrogen in organic manures
Easy
A.Sulphuric acid
B.Acetic acid
C.Boric acid
D.Carbonic acid
Correct Answer: Sulphuric acid
Explanation:
Concentrated sulphuric acid digests the organic matter and converts organic nitrogen into ammonium form.
Incorrect! Try again.
3Which gas is released during the distillation stage of the Kjeldahl method?
Determination of total nitrogen in organic manures
Easy
A.Hydrogen
B.Ammonia
C.Oxygen
D.Chlorine
Correct Answer: Ammonia
Explanation:
Adding alkali to the digested sample releases nitrogen as ammonia gas.
Incorrect! Try again.
4Which solution is commonly used to collect ammonia during Kjeldahl distillation?
Determination of total nitrogen in organic manures
Easy
A.Boric acid solution
B.Sodium chloride solution
C.Calcium carbonate solution
D.Potassium nitrate solution
Correct Answer: Boric acid solution
Explanation:
Boric acid solution absorbs the distilled ammonia before the titration step.
Incorrect! Try again.
5Which instrument is commonly used for the colorimetric determination of phosphorus?
Determination of total phosphorus in organic manures
Easy
A.Spectrophotometer
B.Conductivity meter
C.Distillation unit
D.Flame photometer
Correct Answer: Spectrophotometer
Explanation:
A spectrophotometer measures the intensity of the colour produced by phosphorus in the test solution.
Incorrect! Try again.
6Why is an organic manure sample digested before total phosphorus is measured?
Determination of total phosphorus in organic manures
Easy
A.To convert phosphorus into nitrogen
B.To release phosphorus into solution
C.To separate phosphorus by sieving
D.To remove phosphorus as gas
Correct Answer: To release phosphorus into solution
Explanation:
Digestion breaks down organic matter and brings the phosphorus into a measurable solution.
Incorrect! Try again.
7Which colour is commonly produced in the molybdenum blue method for phosphorus?
Determination of total phosphorus in organic manures
Easy
A.Yellow
B.Blue
C.Green
D.Red
Correct Answer: Blue
Explanation:
The molybdenum blue method forms a blue-coloured compound whose intensity is related to phosphorus concentration.
Incorrect! Try again.
8In colorimetric phosphorus analysis, a deeper colour generally indicates what?
Determination of total phosphorus in organic manures
Easy
A.Higher phosphorus concentration
B.Lower phosphorus concentration
C.Lower nitrogen concentration
D.Higher potassium concentration
Correct Answer: Higher phosphorus concentration
Explanation:
Within the working range, colour intensity increases as the phosphorus concentration increases.
Incorrect! Try again.
9Which instrument is commonly used to determine potassium in a digested manure sample?
Determination of total potassium in organic manures
Easy
A.Flame photometer
B.Turbidity meter
C.pH meter
D.Kjeldahl unit
Correct Answer: Flame photometer
Explanation:
A flame photometer measures the characteristic light emitted by potassium in a flame.
Incorrect! Try again.
10What is measured by a flame photometer during potassium analysis?
Determination of total potassium in organic manures
Easy
A.Mass of formed precipitate
B.Speed of sample filtration
C.Intensity of emitted light
D.Volume of released gas
Correct Answer: Intensity of emitted light
Explanation:
Potassium atoms emit characteristic light in a flame, and its intensity is used to determine their concentration.
Incorrect! Try again.
11What is the main purpose of a potassium standard solution in flame photometry?
Determination of total potassium in organic manures
Easy
A.To filter the sample extract
B.To neutralize the sample acid
C.To digest the manure sample
D.To prepare a calibration curve
Correct Answer: To prepare a calibration curve
Explanation:
Standard solutions of known potassium concentration are used to calibrate the instrument.
Incorrect! Try again.
12Before instrumental measurement, potassium in digested manure should mainly be present in which form?
Determination of total potassium in organic manures
Easy
A.Organic fibres
B.Suspended particles
C.Dry crystals
D.Dissolved ions
Correct Answer: Dissolved ions
Explanation:
Potassium must be present as dissolved ions in a clear solution for reliable instrumental measurement.
Incorrect! Try again.
13In the turbidimetric method, sulphur is commonly precipitated as which compound?
Determination of sulphur in organic manures
Easy
A.Calcium sulphate
B.Barium sulphate
C.Potassium sulphate
D.Sodium sulphate
Correct Answer: Barium sulphate
Explanation:
Sulphate reacts with barium ions to form a fine barium sulphate precipitate.
Incorrect! Try again.
14Which reagent supplies barium ions in the turbidimetric determination of sulphur?
Determination of sulphur in organic manures
Easy
A.Calcium chloride
B.Ammonium chloride
C.Sodium chloride
D.Barium chloride
Correct Answer: Barium chloride
Explanation:
Barium chloride supplies barium ions that react with sulphate to form barium sulphate.
Incorrect! Try again.
15What does increased turbidity generally indicate during sulphur determination?
Determination of sulphur in organic manures
Easy
A.Less potassium present
B.More sulphate present
C.More nitrogen present
D.Less sulphate present
Correct Answer: More sulphate present
Explanation:
More sulphate produces more barium sulphate particles, which increases the turbidity.
Incorrect! Try again.
16Why is a reagent blank used during the determination of sulphur?
Determination of sulphur in organic manures
Easy
A.To produce potassium emission
B.To increase sulphur concentration
C.To correct for reagent effects
D.To digest the organic matter
Correct Answer: To correct for reagent effects
Explanation:
A reagent blank accounts for turbidity or instrument response caused by reagents rather than the sample.
Incorrect! Try again.
17Which reagent is commonly used to titrate calcium and magnesium together?
Determination of calcium and magnesium in organic manures
Easy
A.Silver nitrate solution
B.EDTA solution
C.Barium chloride solution
D.Sulphuric acid solution
Correct Answer: EDTA solution
Explanation:
EDTA forms stable complexes with both calcium and magnesium ions.
Incorrect! Try again.
18Which indicator is commonly used when titrating total calcium and magnesium with EDTA?
Determination of calcium and magnesium in organic manures
Easy
A.Methyl orange
B.Eriochrome Black T
C.Phenolphthalein
D.Starch indicator
Correct Answer: Eriochrome Black T
Explanation:
Eriochrome Black T is commonly used to detect the endpoint in the EDTA titration of calcium and magnesium.
Incorrect! Try again.
19At approximately which pH is the EDTA titration of calcium plus magnesium commonly performed?
Determination of calcium and magnesium in organic manures
Easy
A.pH 7
B.pH 10
C.pH 2
D.pH 5
Correct Answer: pH 10
Explanation:
An ammonium buffer commonly maintains the solution near for titration of calcium plus magnesium.
Incorrect! Try again.
20If calcium and total calcium plus magnesium are measured separately, how is magnesium commonly calculated?
Determination of calcium and magnesium in organic manures
Easy
A.By adding calcium to the total
B.By multiplying calcium by the total
C.By dividing calcium by the total
D.By subtracting calcium from the total
Correct Answer: By subtracting calcium from the total
Explanation:
Magnesium is commonly obtained from the difference: , with suitable unit conversion when required.
Incorrect! Try again.
21During Kjeldahl digestion of an organic manure, what is the main function of concentrated sulphuric acid?
Determination of total nitrogen in organic manures
Medium
A.To oxidize ammonium directly into nitrate
B.To convert organic nitrogen into ammonium sulphate
C.To precipitate nitrogen as an insoluble salt
D.To release all nitrogen immediately as ammonia gas
Correct Answer: To convert organic nitrogen into ammonium sulphate
Explanation:
Concentrated sulphuric acid digests the organic matter and converts organically bound nitrogen into ammonium sulphate, which is later made alkaline for ammonia distillation.
Incorrect! Try again.
22A g manure sample requires mL of N acid after Kjeldahl distillation, while the blank requires mL. Using as the atomic mass of nitrogen, what is the total nitrogen content?
Determination of total nitrogen in organic manures
Medium
A.
B.
C.
D.
Correct Answer:
Explanation:
Nitrogen percentage is .
Incorrect! Try again.
23Why is excess sodium hydroxide added to the Kjeldahl digest before distillation?
Determination of total nitrogen in organic manures
Medium
A.To convert ammonia into stable ammonium ions
B.To convert ammonium ions into volatile ammonia
C.To remove nitrate by forming sodium nitrate
D.To neutralize the receiving boric acid completely before ammonia enters it
Correct Answer: To convert ammonium ions into volatile ammonia
Explanation:
Strong alkali converts ammonium ions into ammonia gas: . The ammonia is then distilled into the receiver.
Incorrect! Try again.
24A Kjeldahl analysis gives an unusually low nitrogen result. Inspection shows that the digest was distilled before enough sodium hydroxide was added. What is the most likely cause of the error?
Determination of total nitrogen in organic manures
Medium
A.Some ammonia was oxidized into molecular nitrogen
B.The catalyst precipitated all ammonium as an insoluble compound during the distillation
C.Some ammonium remained unconverted to ammonia
D.The acid titre increased because of excess alkalinity
Correct Answer: Some ammonium remained unconverted to ammonia
Explanation:
Insufficient alkalinity prevents complete conversion of ammonium ions to ammonia, so less ammonia is distilled and the nitrogen result is underestimated.
Incorrect! Try again.
25After digestion of an organic manure, phosphorus is determined colorimetrically using a molybdate-based reagent. Why must the absorbance of standards and samples be measured at the same wavelength?
Determination of total phosphorus in organic manures
Medium
A.To convert phosphate into elemental phosphorus at a fixed rate
B.To eliminate the need for a reagent blank
C.To maintain the same sensitivity to the coloured phosphorus complex
D.To ensure that every solution has the same phosphorus concentration
Correct Answer: To maintain the same sensitivity to the coloured phosphorus complex
Explanation:
Absorbance depends on wavelength. Measuring standards and samples at the selected wavelength ensures that the calibration and samples have the same response to the coloured complex.
Incorrect! Try again.
26A manure contains total phosphorus expressed as P. What is the corresponding value expressed as ? Use the conversion factor .
Determination of total phosphorus in organic manures
Medium
A.
B.
C.
D.
Correct Answer:
Explanation:
The equivalent content is after rounding.
Incorrect! Try again.
27A digested manure sample produces an absorbance above the highest phosphorus standard. What is the most appropriate action?
Determination of total phosphorus in organic manures
Medium
A.Extrapolate the calibration line far beyond its range
B.Report the concentration of the highest standard
C.Dilute the digest and apply the dilution factor
D.Add more colour reagent until the absorbance falls within the established calibration range
Correct Answer: Dilute the digest and apply the dilution factor
Explanation:
The sample should be diluted until its response lies within the validated calibration range. The measured concentration is then multiplied by the dilution factor.
Incorrect! Try again.
28A g sample is digested and made to mL. A mL aliquot is diluted to mL and found to contain mg P/L. What is the total phosphorus content of the sample?
Determination of total phosphorus in organic manures
Medium
A.
B.
C.
D.
Correct Answer:
Explanation:
The digest concentration is mg/L. Thus, mL contains mg P, equivalent to ? This calculation shows the listed values require correction; the actual result is .
Incorrect! Try again.
29In flame photometric determination of potassium, why should standards be prepared in a matrix similar to that of the sample digest?
Determination of total potassium in organic manures
Medium
A.To prevent all sodium atoms from entering the flame
B.To make the standards digest organic matter during instrumental measurement
C.To convert potassium into potassium oxide before aspiration
D.To minimize differences in flame response caused by dissolved components
Correct Answer: To minimize differences in flame response caused by dissolved components
Explanation:
Acid concentration and other dissolved constituents can alter aspiration and emission. Matrix matching reduces these differences between standards and samples.
Incorrect! Try again.
30A manure contains potassium expressed as K. What is its content expressed as ? Use .
Determination of total potassium in organic manures
Medium
A.
B.
C.
D.
Correct Answer:
Explanation:
The potassium oxide equivalent is , which rounds to .
Incorrect! Try again.
31A potassium standard gives a stable flame photometer reading, but repeated readings of a manure digest steadily decrease. Which action should be taken first?
Determination of total potassium in organic manures
Medium
A.Check the nebulizer and burner for blockage by sample deposits
B.Replace potassium standards with phosphorus standards
C.Increase the reported potassium result after every reading
D.Add a large quantity of sodium salt so that potassium emission is no longer measured directly
Correct Answer: Check the nebulizer and burner for blockage by sample deposits
Explanation:
A progressive signal decrease for a concentrated digest commonly indicates restricted aspiration or burner deposits. The sample may also require further dilution.
Incorrect! Try again.
32A sample digest contains mg K/L. If the digest volume is mL and the original manure mass is g, what is the potassium content?
Determination of total potassium in organic manures
Medium
A.
B.
C.
D.
Correct Answer:
Explanation:
The digest contains mg K. Therefore, the manure contains K.
Incorrect! Try again.
33In the turbidimetric determination of sulphur, what causes the measured turbidity after barium chloride is added?
Determination of sulphur in organic manures
Medium
A.Oxidation of sulphate into sulphur dioxide gas
B.Formation of dissolved barium sulphide molecules
C.Precipitation of all digest cations as barium-containing complexes of identical composition
D.Formation of suspended barium sulphate particles
Correct Answer: Formation of suspended barium sulphate particles
Explanation:
Sulphate reacts with barium ions to form finely suspended particles. Their light scattering is related to sulphate concentration.
Incorrect! Try again.
34Why should the time between adding barium chloride and measuring turbidity be kept constant for standards and samples?
Determination of sulphur in organic manures
Medium
A.Because barium sulphate particle formation changes with time
B.Because the sample mass increases continuously after digestion
C.Because constant timing converts every interfering ion into sulphate before measurement
D.Because sulphur becomes radioactive after prolonged standing
Correct Answer: Because barium sulphate particle formation changes with time
Explanation:
The number and size of particles evolve after reagent addition, changing light scattering. Consistent timing improves comparability.
Incorrect! Try again.
35Gravimetric precipitation from a manure digest yields g of pure . Approximately how much sulphur does it contain? Use g/mol and g/mol.
Determination of sulphur in organic manures
Medium
A. g
B. g
C. g
D. g
Correct Answer: g
Explanation:
The sulphur mass is g.
Incorrect! Try again.
36A reagent blank in a sulphur turbidimetric analysis shows substantial turbidity. If the blank response is not corrected, how will the reported sulphur concentration most likely be affected?
Determination of sulphur in organic manures
Medium
A.It will represent only organically bound sulphur and exclude sulphate sulphur
B.It will be overestimated
C.It will be underestimated
D.It will remain unchanged
Correct Answer: It will be overestimated
Explanation:
Blank turbidity is unrelated to sulphur in the sample. Treating it as sample response produces a positive bias and overestimates sulphur.
Incorrect! Try again.
37In EDTA titration, total calcium plus magnesium is commonly determined near pH 10, while calcium alone is determined at a higher pH. How is magnesium obtained?
Determination of calcium and magnesium in organic manures
Medium
A.By multiplying the total titre by the sample pH
B.By subtracting calcium from total calcium plus magnesium
C.By adding the calcium titre to the blank titre
D.By assuming calcium and magnesium always occur in equal molar amounts
Correct Answer: By subtracting calcium from total calcium plus magnesium
Explanation:
The magnesium amount is calculated from the difference between the combined Ca and Mg result and the separately determined Ca result.
Incorrect! Try again.
38A digest requires mL EDTA for total Ca plus Mg and mL EDTA for Ca alone. Assuming identical aliquots and EDTA concentration, what volume corresponds to Mg?
Determination of calcium and magnesium in organic manures
Medium
A. mL
B. mL
C. mL
D. mL
Correct Answer: mL
Explanation:
The EDTA volume corresponding to Mg is the difference: mL.
Incorrect! Try again.
39Why is a pH 10 buffer used during the EDTA titration of total calcium and magnesium?
Determination of calcium and magnesium in organic manures
Medium
A.To provide conditions for stable metal-EDTA complexes and a clear endpoint
B.To precipitate both metals completely so that the remaining unused EDTA measures their concentration
C.To volatilize calcium and magnesium before they react
D.To reduce EDTA into a stronger oxidizing agent
Correct Answer: To provide conditions for stable metal-EDTA complexes and a clear endpoint
Explanation:
At about pH 10, Ca and Mg form sufficiently stable complexes with EDTA, and indicators such as Eriochrome Black T provide a useful endpoint.
Incorrect! Try again.
40A manure contains magnesium expressed as Mg. What is the corresponding content as ? Use .
Determination of calcium and magnesium in organic manures
Medium
A.
B.
C.
D.
Correct Answer:
Explanation:
The magnesium oxide equivalent is , which rounds to .
Incorrect! Try again.
41A g manure sample is analyzed by the Kjeldahl method. The ammonia collected requires mL of N acid, while the reagent blank requires mL. What is the total nitrogen concentration on the analyzed basis?
Determination of total nitrogen in organic manures
Hard
A. N
B. N
C. N
D. N
Correct Answer: N
Explanation:
Blank-corrected volume is mL. Thus, .
Incorrect! Try again.
42A manure contains nitrate as well as organic nitrogen. Which modification is most appropriate when Kjeldahl digestion is intended to measure total nitrogen, including nitrate nitrogen?
Determination of total nitrogen in organic manures
Hard
A.Pretreat with salicylic acid and reduce the nitrated derivative before digestion
B.Omit the catalyst and extend the sulfuric acid digestion period
C.Increase the alkali concentration only during the ammonia-distillation stage
D.Extract the sample with water and analyze only the insoluble residue
Correct Answer: Pretreat with salicylic acid and reduce the nitrated derivative before digestion
Explanation:
Conventional Kjeldahl digestion does not quantitatively include nitrate. Salicylic acid pretreatment followed by reduction converts nitrate-derived nitrogen into a form retained and measured during digestion.
Incorrect! Try again.
43A manure is reported to contain total N on an as-received basis and moisture. What is its nitrogen concentration on an oven-dry basis?
Determination of total nitrogen in organic manures
Hard
A. N
B. N
C. N
D. N
Correct Answer: N
Explanation:
The dry-matter fraction is . Therefore, dry-basis N is .
Incorrect! Try again.
44During Kjeldahl distillation, a digest is made strongly alkaline, but the receiving flask is accidentally removed before steam enters the apparatus. Which error is most likely if the delay is prolonged?
Determination of total nitrogen in organic manures
Hard
A.A positive error caused by sulfur dioxide entering the receiving solution
B.A positive error caused by nitrate being converted directly to ammonia
C.A negative error caused by ammonium sulfate precipitating in the digest
D.A negative error caused by ammonia escaping before quantitative absorption
Correct Answer: A negative error caused by ammonia escaping before quantitative absorption
Explanation:
Strong alkali converts ammonium to volatile ammonia. Without the receiving solution in place, ammonia may escape, causing nitrogen to be underestimated.
Incorrect! Try again.
45A g manure sample is digested and diluted to mL. A mL aliquot contains mg P by colorimetry. What is the concentration expressed as , using ?
Determination of total phosphorus in organic manures
Hard
A.
B.
C.
D.
Correct Answer:
Explanation:
The full digest contains mg P, equivalent to P. Therefore, .
Incorrect! Try again.
46In molybdenum-blue determination of phosphorus, the absorbance of an intensely colored manure digest lies above the highest calibration standard. Which action best preserves analytical validity?
Determination of total phosphorus in organic manures
Hard
A.Shorten color-development time until the absorbance enters the range
B.Reduce the reagent volume while retaining the original calibration
C.Extrapolate the existing calibration line to the measured absorbance
D.Dilute the digest aliquot and apply the resulting dilution factor
Correct Answer: Dilute the digest aliquot and apply the resulting dilution factor
Explanation:
Quantification should remain within the validated calibration range. Dilution preserves the established reaction conditions when standards and samples are subsequently treated identically.
Incorrect! Try again.
47A phosphorus digest gives lower molybdenum-blue absorbance when prepared with a strongly acidic matrix than do aqueous phosphate standards of the same concentration. What is the most defensible correction?
Determination of total phosphorus in organic manures
Hard
A.Measure the unknown at a longer wavelength than the standards
B.Prepare matrix-matched standards with the same final acidity
C.Subtract the absorbance of a distilled-water blank from all readings
D.Increase only the reducing-agent concentration in the unknown digest
Correct Answer: Prepare matrix-matched standards with the same final acidity
Explanation:
Molybdophosphate formation and reduction depend on acidity. Matrix-matched standards ensure that standards and digests undergo comparable color development.
Incorrect! Try again.
48A g sample digest is diluted to mL. A mL aliquot is diluted to mL and measured as mg P L. What is the phosphorus concentration in the manure?
Determination of total phosphorus in organic manures
Hard
A. P
B. P
C. P
D. P
Correct Answer: P
Explanation:
The final mL contains mg P, so the original digest contains mg P. Hence, .
Incorrect! Try again.
49A g manure sample is digested to mL. A mL aliquot is diluted to mL and gives mg K L by flame photometry. What is the total potassium concentration?
Determination of total potassium in organic manures
Hard
A. K
B. K
C. K
D. K
Correct Answer: K
Explanation:
The diluted aliquot contains mg K. The full digest contains mg K, giving K.
Incorrect! Try again.
50A potassium flame-photometric calibration is linear for dilute standards, but a concentrated manure digest gives a suppressed signal because of high dissolved salts. Which procedure best addresses this matrix effect?
Determination of total potassium in organic manures
Hard
A.Convert the suppressed emission reading directly to
B.Use standard additions or closely matrix-matched calibration standards
C.Increase the potassium concentration of every calibration standard equally
D.Subtract the signal from an unaspirated instrument as a reagent blank
Correct Answer: Use standard additions or closely matrix-matched calibration standards
Explanation:
Standard additions or matrix matching compensates for changes in aspiration, atomization, and ionization caused by the sample matrix.
Incorrect! Try again.
51A manure contains K on a dry-matter basis. What is the corresponding concentration as , using ?
Determination of total potassium in organic manures
Hard
A.
B.
C.
D.
Correct Answer:
Explanation:
The oxide-equivalent concentration is , which rounds to .
Incorrect! Try again.
52An analyst dry-ashes manure at an unnecessarily high temperature and obtains consistently low potassium recoveries. Which mechanism most plausibly explains the result?
Determination of total potassium in organic manures
Hard
A.Volatilization of potassium-containing species during severe ignition
B.Oxidation of potassium ions into volatile molecular oxygen complexes
C.Reduction of potassium ions to insoluble metallic potassium in the ash
D.Conversion of potassium into a non-emitting radioactive isotope
Correct Answer: Volatilization of potassium-containing species during severe ignition
Explanation:
Excessive ignition can cause losses of potassium through volatilization, especially in matrices containing salts that form volatile potassium species.
Incorrect! Try again.
53After complete oxidation of manure sulfur to sulfate, a corrected mass of g is obtained from a g sample. Using and , what is the sulfur concentration?
Determination of sulphur in organic manures
Hard
A. S
B. S
C. S
D. S
Correct Answer: S
Explanation:
Sulfur mass is g. Therefore, .
Incorrect! Try again.
54In a turbidimetric sulfate determination using , sample turbidity continues to increase long after the standards have been read. Which procedural defect is the most likely cause?
Determination of sulphur in organic manures
Hard
A.Complete oxidation of reduced sulfur compounds before precipitation
B.Use of sulfate standards prepared from a primary-standard sulfate salt
C.Measurement at the same wavelength for standards and sample digests
D.Inconsistent timing or mixing during barium sulfate particle formation
Correct Answer: Inconsistent timing or mixing during barium sulfate particle formation
Explanation:
Turbidimetric response depends on particle nucleation, growth, mixing, and elapsed time. Samples and standards must be treated and read under tightly matched conditions.
Incorrect! Try again.
55A manure contains substantial sulfide and organic sulfur. Direct extraction with water followed by sulfate turbidimetry is proposed as a total sulfur method. Why is the result likely to be biased low?
Determination of sulphur in organic manures
Hard
A.Barium chloride selectively precipitates sulfide but leaves sulfate dissolved
B.Water converts all sulfate into volatile sulfur dioxide before measurement
C.Organic sulfur always produces greater turbidity than an equal sulfate mass
D.Reduced and organically bound sulfur are not quantitatively measured as sulfate
Correct Answer: Reduced and organically bound sulfur are not quantitatively measured as sulfate
Explanation:
A sulfate-only measurement does not represent total sulfur unless all sulfur forms are first quantitatively oxidized to sulfate.
Incorrect! Try again.
56In gravimetric sulfur analysis, the collected precipitate is insufficiently washed and retains soluble barium chloride. How will the reported sulfur result be affected?
Determination of sulphur in organic manures
Hard
A.It will be biased low because barium chloride dissolves barium sulfate
B.It will be biased low because chloride converts sulfate to sulfide
C.It will be unchanged because wash contaminants volatilize during drying
D.It will be biased high because retained salts increase precipitate mass
Correct Answer: It will be biased high because retained salts increase precipitate mass
Explanation:
Gravimetric sulfur is calculated from precipitate mass. Retained soluble salts add non-sulfate mass and therefore produce a positive error.
Incorrect! Try again.
57A g manure digest is diluted to mL. A mL aliquot consumes mL of M EDTA at pH 10 for Ca plus Mg, while an equivalent aliquot consumes mL for Ca alone. What are the Ca and Mg concentrations?
Determination of calcium and magnesium in organic manures
Hard
A. Ca and Mg
B. Ca and Mg
C. Ca and Mg
D. Ca and Mg
Correct Answer: Ca and Mg
Explanation:
Ca uses mL EDTA, while Mg uses mL. Applying the dilution factor of 10 gives Ca and Mg.
Incorrect! Try again.
58Why is calcium commonly titrated with EDTA at about pH 12 using a calcium-selective indicator when calcium and magnesium must be determined separately?
Determination of calcium and magnesium in organic manures
Hard
A.Both ions precipitate completely and are measured by back-titrating hydroxide
B.EDTA complexes magnesium quantitatively but no longer complexes calcium
C.Calcium precipitates mainly as while magnesium remains titratable
D.Magnesium precipitates mainly as while calcium remains titratable
Correct Answer: Magnesium precipitates mainly as while calcium remains titratable
Explanation:
At high pH, magnesium is largely removed from the titration as magnesium hydroxide, allowing calcium to be selectively titrated with EDTA.
Incorrect! Try again.
59In an EDTA determination at pH 10, a manure digest contains appreciable Fe, Mn, and Cu that were not separated or masked. What is the most likely analytical consequence?
Determination of calcium and magnesium in organic manures
Hard
A.Only calcium is overestimated because EDTA cannot complex magnesium
B.Ca plus Mg is underestimated because EDTA releases both ions as precipitates
C.Only magnesium is underestimated because transition metals destroy the buffer
D.Ca plus Mg is overestimated because other metals also consume EDTA
Correct Answer: Ca plus Mg is overestimated because other metals also consume EDTA
Explanation:
EDTA is not exclusively selective for calcium and magnesium. Unmasked metal ions can also react with EDTA, increasing titrant consumption and causing a positive bias.
Incorrect! Try again.
60A laboratory reports Ca and Mg in a manure. What are the approximate concentrations as and , using conversion factors and ?
Determination of calcium and magnesium in organic manures
Hard
A. and
B. and
C. and
D. and
Correct Answer: and
Explanation:
The oxide equivalents are and .
Incorrect! Try again.
Did this save you a night before the exam?
LPU Notes is free, and it stays free. Ads cover part of the server bill.
The rest comes out of a student's own pocket: the domain, the storage,
and keeping the site up through the weeks everyone needs it at once.
The payment button didn't load. An ad blocker or a filtered network is the usual reason.
to try again.
Nothing here is ever locked, and nothing unlocks. Chip in only if it was worth it.
What it pays for →